Avaya CMC1 Manual Do Utilizador

Página de 370
Completing Installation and Cable Pinouts
152 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Enable Alarm Origination to INADS
No External Modem Installed (or No Alarm Origination to INADS)
To enable alarms when no external modem is present:
1. Type change system-parameters maintenance and press Enter
2. Type n in the 
Alarm Origination Activated to OSS Numbers
 field and press 
Enter. 
3. For some DEFINITY ECS software releases, enable 
Cleared Alarm Notification 
and Restart Notification
 before the submitting the form.
External Modem Installed
To enable alarms when an external modem is present:
1. Type change system-parameters maintenance and press Enter
2. Type y in the 
Alarm Origination Activated to OSS Numbers
 field and press 
Enter. 
3. For some DEFINITY ECS software releases, enable 
Cleared Alarm Notification
 
and 
Restart Notification
 before the submitting the form.
4. Be sure the system is part of the INADS database by calling the INADS Database 
Administrator at the Technical Service Center (TSC). Verify that INADS can dial into the 
system and that the system can dial out to INADS. 
As part of the system registration process, the INADS Database Administrator enables 
Alarm Origination and customer options.
Note:
Note:
When calling from a remote modem, you may need to disable error correction to 
allow the modems to connect successfully. For example, the AT&T Paradyne 
KeepInTouch
®
 modem may require the “AT\n0” command.
Register the Switch for Maintenance
The Automatic Registration Tool (ART) is a web-based tool that permits Avaya field technicians 
and Remote Technical Services (RTS) Database Administration (DBA) to register Avaya direct 
channel products.
The product that you are registering must have switch connectivity through:
the INADS line
an IP address