Avaya CMC1 Manual Do Utilizador

Página de 370
Upgrading R6csi/R7csi/R8csi to Avaya Communication Manager on an Avaya DEFINITY Server CSI
196 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Verify the Upgrade
To verify the upgrade:
1. Type status system 1 and verify that the system is in a normal state.
2. Type display alarms and press Enter.
If the system is not alarm-free, take the needed corrective actions.
3. Type list configuration software-version and press Enter. Verify the Avaya 
Communication Manager configuration.
4. Type display communication links and press Enter.
Status each of the links.
Note:
Note:
ISDN-PRI D-channel links no longer appear on this screen. (For Release 7 and 
later, ISDN-PRI resides on the network packet circuit pack.) For Release 7 and 
later, the only way to determine if an ISDN-PRI D-Channel is up is to type status 
signaling group
 and press Enter.
5. Type list signal press Enter. For each signal, type status signal and press Enter.
Note:
Note:
Check the ISDN-PRI D-channel links here.
6. Execute the following commands and verify that the information is correct:
list station 
list trunk-group 
list hunt-group 
list data-module 
Enable Scheduled Maintenance
To enable scheduled maintenance:
1. Type change system-parameters maintenance and press Enter.
2. Check the 
Start Time
 and 
Stop Time
 fields.