Task table
Issue 10 June 2005
219
 
3. Type display errors and press RETURN
4. Examine the Hardware Error Log and record any Error Code 18 alarm that identifies 
existing busyouts. After the upgrade you will restore the busyouts as they were.
5. Execute the following commands to see whether the switch has administration:
list station 
list trunk-group 
list hunt-group 
list data-module 
list announcements 
If any command does not complete successfully, escalate the problem immediately. After the 
upgrade you will check the same administration to ensure that the translations are intact.
Disable scheduled maintenance 
and alarm origination
To prevent scheduled daily maintenance from interfering with the upgrade:
1. Type change system-parameters maintenance and press RETURN.
2. If scheduled maintenance is in progress, set the 
Stop Time
 field to 1 minute after the 
current time.
or
If scheduled maintenance is not in progress, set the 
Start Time
 field to a time after the 
upgrade will be completed. 
For example, if you start the upgrade at 8:00 P.M. and the upgrade takes 90 minutes, set 
the 
Start Time
 field to 21:30.
!
CAUTION:
CAUTION:
If you do not disable Alarm Origination, the system can generate alarms, 
resulting in unnecessary trouble tickets.
3. Type neither in the 
Alarm Origination to OSS Numbers
 field and press ENTER 
Note:
Note:
Disabling alarm origination prevents the system from generating alarms, thus 
preventing unnecessary trouble tickets.