Adding or Removing Hardware
316 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Figure 97: Typical nonsignaling wideband configuration
If using a CSU, the distance between connections may be up to 1300 ft. (397.2 m). The 
maximum distance to the endpoint depends on the type of cable and the specifications of the 
endpoint.
Signaling configuration
A signaling connection from the system to a wideband endpoint passes through a bandwidth 
controller. The distance between the system and the bandwidth controller depends on the type 
of cable and controller. 
 shows connections with and without a CSU.
Figure notes:
1. Wideband endpoint (wire per manufacturer)
2. Modular cord
3. 103A or modular wall jack
4. Channel service unit (CSU)
5. H600-307 cable to DTE connector on CSU
6. DS1/E1 circuit pack 
7. Main distribution frame (MDF)
8. Distance limit depends on cable and 
endpoint type. 
9. A25D 25-pair cable (male-to-male)
cydf049 RPY 123097
AUX PORT COM PORT
MODEM
DTE
NETWORK
POWER
1
1
2
2
3
3
4
5
6
6
7
8
9