Replacing an AC Power Supply
NetScreen-5000 Series 
37
R
EPLACING
 
AN
 AC P
OWER
 S
UPPLY
To replace an AC power supply:
1.
Turn off the power supply.
2.
Lift the AC power cord retainer clip.
3.
Unplug the cord from the power supply.
4.
Turn the thumbscrew counterclockwise to release the power supply.
5.
Lift and grip the lever, and then gently pull the power supply straight out.
6.
Insert the new power supply into the bay.
7.
Secure the power supply in place by tightening the thumbscrew clockwise.
8.
Lift the retainer clip, and then plug the power cord into the power supply.
9.
Press the retainer clip over the cord, securing it in place.
R
EPLACING
 
THE
 F
AN
 M
ODULE
The front panel of each device includes an air vent for cooling purposes. The NetScreen-
5000 Series fan modules differ according to the device model:
The NetScreen-5200 fan module has three fans
The NetScreen-5400 fan module has two fans
When a fan or fan module fails, the Fan LED glows red, and the system generates an 
event alarm and a SNMP trap. Although a NetScreen-5000 Series system can operate 
with a fan out of service, it is advisable to replace the fan module as soon as possible.
When you remove the fan module, you must reinstall it (or replace it) within two minutes, 
or system failure can occur.
If the temperature alarm continues to display, we recommend inspecting the fan filter. To 
remove a filter cover and replace a filter, use the procedures described in this section.
Warning: 
If the device becomes too hot, then the system shuts down automatically.
Note: 
During the one-year warranty period, you can obtain a replacement fan module by 
contacting Juniper Networks Technical support. After the warranty period, contact the 
Juniper Networks Sales department to renew your support contract.
Note: 
Depending on the working environment where the device is located, we recommend 
changing the fan filter every six months. The fan filter SKU number is NS-5200-FLTR or 
NS-5400-FLTR.