Fujitsu V01 Manual Do Utilizador

Página de 138
Chapter 3  Web Operation 
IP-900 Series 
92 
Table 3-25  Encoder Operation & Status Display Items 
Item Display 
Main Encoder 
{Operating / Stopped} 
Displays the operation status as the result of setting in the Settings window or the 
operation of the encoding START or STOP button. 
 
Number of possible streams: N 
Destination IP address: Port number {Normal / Fault} 
N=1    If "Multicast" or "Unicast (simplex)" is specified for [Streaming mode], the 
value is fixed to "1". 
1-4    If "Unicast" is specified for [Streaming mode], a value from "1" to "4" is 
displayed.  The number of possible streams depends on the [System bit rate] and 
[Acceptable stream number] settings. 
Displays whether an error occurred for each streaming destination IP address. 
Sub Encoder 
{Operating / Stopped} 
Displays the operation status as the result of setting in the Settings window or the 
operation of the encoding START or STOP button. 
 
Number of possible streams: N 
Destination IP address: Port number {Normal / Fault} 
N=1    If "Multicast" or "Unicast (simplex)" is specified for [Streaming mode], the 
value is fixed to "1". 
1-4    If "Unicast" is specified for [Streaming mode], a value from "1" to "4" is 
displayed.  The number of possible streams depends on the [System bit rate] and 
[Acceptable stream number] settings. 
Displays whether an error occurred for each streaming destination IP address. 
Video input 
{Normal / Fault / No video signal} 
Displays the input state of the video signal. 
* Notation:  {A/B} indicates that either A or B is displayed. 
 
 
The maximum system bit rate when the streaming and recording are activated simultaneously is 
limited up to 14.049 Mbps 
 
Recording and simultaneous streaming using the sub encoder are limited to cases in which [Video 
resolution] is "352 x 240," "352 x 288," "176 x 112," or "176 x 144" as described in Sub encoder settings 
(Encode) in Section 3.3.1, "Setting (Encoder)."