Maintenance
6
Turn the projector back over.
7
Connect the power cord and turn the 
projector to standby mode.
8
Press the following keys on the 
control panel in the following order 
for less than five seconds each: 
RESET, 
<, ,, ENTER.
• Be sure to use the LMP-C120  Projector 
Lamp for replacement. If you use lamps 
other than LMP-C120, the projector may 
cause a malfunction.
• Be sure to turn off the projector and unplug 
the power cord before replacing the lamp.
• Do not put your hands into the lamp 
replacement spot, or not fall any liquid or 
object into it to avoid electrical shock or fire.
The air filter should be cleaned every 300 
hours. When it becomes difficult to remove 
the dust from the filter, replace the filter with 
a new one. 
To clean the air filter, follow the steps 
below:
1
Turn off the power and unplug the 
power cord. 
2
Turn the projector over.
3
Remove the air filter cover.
4
Remove the dust from the filter with a 
vacuum cleaner.
5
Attach the air filter and replace the 
cover. 
• If the air filter is excessively dirty, wash it 
with mild detergent solution and dry it in a 
shaded place. If the dust cannot be removed, 
replace the air filter with the supplied new 
one.
• Be sure to attach the air filter cover firmly; 
the power will not be turned on if it is not 
closed securely.
• The air filter has a face and a reverse side. 
Place the air filter so that it fits in a notch on 
the air filter cover.
Notes
Cleaning the Air Filter
Notes