X1000.5 Owners Manual
You  can  position  this  amplifier  most  anywhere  you  wish,  but  it  re-
quires  adequate  ventilation.    We  do  not  recommend  placing  it  in 
enclosed cabinets or small closets without means for air to circulate 
freely.  Stacking these power amplifiers directly upon each other is not 
recommended for the same reason. This amplifier idles at about 700 
watts, most of  which dissipates as heat across the heatsinks. As a point 
of  reference, these heatsinks should never become too hot to touch 
for several seconds.
Let’s talk about AC power requirements.  This amplifier draws about 
6 amps (continuous rms) at 120 volts out of  the wall during normal 
operation, and this power draw reflects mostly the idle current that 
we run through the output stage.  If  you are driving a low impedance 
load, you will draw more power than this, but this will not be typical.
The  amplifier’s  voltage  and  current  rating  are  indicated  on  the  rear 
panel.  It will be 240 volts, 220 volts, 120 volts or 100 volts, all with 
an appropriate rear mounted resetable circuit breaker.  The frequency 
rating of  the AC line source in all instances will be 50 to 60 Hz.  Please 
verify that the amplifiers indicated voltage requirements are consistent 
with the line voltage supplied at your location.
The  Pass  Laboratories™  X1000.5  is  provided  with  a  conventional 
IEC detachable AC line cord, which is rated at 20 amps. The safety 
ground is attached to the chassis in the conventional approved man-
ner.  The AC power input to the amplifier runs through a RF filter, 
which removes high frequency noise coming into and going out of  the 
amplifier power supply.
Under no circumstances should you defeat the ground connection of  
the power cord.  For your safety, the chassis of  the amplifier should be 
earth grounded.  Signal ground is isolated from chassis, safety ground, 
to  reduce  the  incidence  of   ground  loop  noise.    The  presence  of   a 
safety ground will not degrade the audio signal chain.  
You  may  substitute an  aftermarket  detachable  IEC  320  style power 
cord of  your choosing; provided it is rated for at least 15 amps and it 
meets all legal requirements and has been approved by the local testing 
authority for such things.
Looking at the rear panel you will see the IEC 320 AC power cord 
receptacle,  a  thermal  magnetic  breaker  switch,  two  pairs  of   output 
connectors, a pair of  binding post connectors for remote turn-on, one 
RCA input connector and one XLR balanced input connector.
Make sure that the breaker switch is off  (down).  Plug the AC cord 