Rev. 0 | Page 14 of 24 
ABSOLUTE MAXIMUM RATINGS—ADSST-73360LAR 
 (T
A
 = 25°C unless otherwise noted) 
Table 8. 
Parameter Rating 
AVDD, DVDD to GND 
–0.3 V to +4.6 V 
AGND to DGND 
–0.3 V to +0.3 V 
Digital I/O Voltage to DGND 
–0.3 V to DVDD + 0.3 V 
Analog I/O Voltage to AGND 
–0.3 V to AVDD  
Operating Temperature Range 
0°C to +70°C 
Storage Temperature Range 
–65°C to +150°C 
Maximum Junction Temperature 
150°C 
Thermal Impedance θ
JA
 (SOIC)  
75°C/W 
 
Stresses above those listed under Absolute Maximum Ratings 
may cause permanent damage to the device. This is a stress 
rating only; functional operation of the device at these or any 
other conditions above those listed in the operational sections 
of this specification is not implied. Exposure to absolute 
maximum rating conditions for extended periods may affect 
device reliability. 
 
 
ESD CAUTION 
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the 
human body and test equipment and can discharge without detection. Although this product features 
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy 
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance 
degradation or loss of functionality.