3.13.4   Adjusting the tension of the stack processing motor belt
(3)
Loosen the screw on the tension arm plate.
(The tension arm plate will be pulled under
tension by the tension spring.)
Fig. 3-1310
Fig. 3-1311
Screw
Grip unit
Screw
Screw
Tension arm plate
(1)
Remove the right inner cover and the rear
cover.
(2)
Remove the 2 mounting screws, and detach
the grip unit.