Printek FormsPro 4300 Manual Do Utilizador

Página de 105
Optional Coaxial/Twinaxial Interface
Page C-5
Option Switches When Configured for Twinaxial Operation
The dipswitches as shown above have the following meanings when the interface is
configured for twinaxial operation.  An asterisk (*) indicates the factory default setting.
Switch/Position
Function
SW1-1 SW1-2
Select Emulation
OFF*
OFF*
4214 Model 2.
ON
OFF
5225 Model 3.
OFF
ON
5256 Model 3
ON
ON
Reserved for future use.
SW1-3 OFF*
Reserved for factory use.
SW1-4 OFF*
Reserved for factory use.
SW1-5 SW1-6
Default Character Set.
OFF*
OFF*
Multinational.
ON
OFF
U.S.A.
 
OFF
ON
Austrian/German.
ON
ON
French Canadian.
SW1-7 SW1-8
Parallel Multiplexer Timeout.
OFF*
OFF*
Short (15 seconds).
ON
OFF
Medium.
OFF
ON
Long.
ON
ON
Very Long (60 seconds).
SW2-1 OFF*
Run.
SW2-1 ON
Test.
  
Addr 0-6 = Code Dump.
  
Addr 7 = Configuration Printout.
  
Addr 8 = Print Test.
  
Addr 9 = Loop Test.
SW2-2 OFF*
Send 5E Hex (^) for Logical Not.
SW2-2 ON
Send E1 Hex ( ) for Logical Not.
SW2-3 OFF*
Load Forms Enabled.
SW2-3 ON
Load Forms Disabled.
SW2-4 OFF*
Reserved for future use.
Twinaxial Address Switch
The “ADDR” switch sets the logical device address.  You may wish to use a small
screwdriver to turn the knob on this switch.  Note that there is a black line on the side of this
knob which indicates the address that is currently selected.  Only addresses 0 through 6 are
valid for twinaxial operation.  Addresses 7, 8, and 9 are used for diagnostic purposes only and
are described later in this appendix in the section titled “Coaxial/Twinaxial Interface
Diagnostics”.