Printronix P7000 Manual Do Utilizador

Página de 402
Chapter 4
Coax/Twinax (CTHI) Emulation
182 
Prt Partial Line
Enable (default). Forces the printer to print a partial line (i.e., 
line not ending with a LF) before moving to the top of form on 
the next page. 
Disable. The last partial line of data will not be printed. 
Device ID
This parameter defines the printer emulation as 4234-2 or 5225. 
After the emulation has been changed, a POR status is sent to the 
host. 4234-2 is the default.
Device Address
Allows you to set the device address from 0 through 6. The host 
directs data and commands on the twinax line to a specific device 
based on its unique device address. After the address has been 
changed, a POR status is sent to the host.
5225 World Trade
The 5225 emulation has a standard multinational character set that 
serves as a base and 14 extended world trade character set 
assortments.
Cancel IGP/DCU
Enable (default). Cancels all buffers when a job is put on hold 
from the host or the CANCEL key is pressed.
Disable. Does not cancel any internal buffer in the printer when 
a job is put on hold from the host or the CANCEL key is 
pressed.