16    DRYPRO MODEL 752 Operation Manual Ver.0.11 2002.6
4. Maintenance Mode
4-1. Function of Maintenance Mode
This device has the maintenance mode that executes maintenance functions.
Touching [MAINTENANCE] on the control panel on OFF LINE will switch into the maintenance mode
and display the maintenance screen on the control panel.
In addition to the maintenance operations, the START TIMER function can be set, and re-printing of the
data that has already been printed can be made, etc. 
The print data from the diagnostic device cannot be received or printing cannot be made in the mainte-
nance mode.
The following shows the maintenance items that can be selected/executed in the maintenance mode.
No.
Display
Description
1
START TIMER
Sets the START TIMER function to ON/OFF, and sets the start-up time for
each day.
The START TIMER screen will appear. (Refer to 
2
TIME SET
Sets the time of the clock of the device. The TIME SET screen will appear.
(Refer to 
3
PREVIOUS PRINT
Re-prints the saved data that has been already printed out (PREVIOUS data).
The PREVIOUS PRINT screen will appear. (Refer to 
.)
4
CALIBRATION
Prints the calibration sheet and corrects the density on the film. (Refer to
5
TEST PRINT
Prints out the SMPTE pattern to control the density.
The TEST PRINT screen will appear. (Refer to 
6
COVER OPEN
Open the front cover. (Refer to 
.)
7
PANEL ADJUST
Adjusts the LCD contrast, the brightness of the backlight, and the touch area
in the touch panel.
The PANEL ADJUST screen will appear. (Refer to 
.)
8
QUEUE CLEAR
Clears the data queued in the device that has not been printed yet.
The QUEUE CLEAR screen will appear. (Refer to 
.)
9
COLD START
Cold-starts (re-start) the device. (Refer to 
.)
CAUTION
When the device is re-started by COLD START, all
of the print data queued for printing and the saved
data that has been already printed out will be
deleted.
10
FILM DATA
Confirms the sum of film. Sets the types of film to be counted, and date on
which film is counted. (Refer to 
.)
11
PRINT CONDITION
Sets the print preferences for each of the connected diagnostic devices.
(Refer to 
12
USER LUT
Creates user's own LUT curve, and applies it to the diagnostic device. (Refer
to 
13
FILMSET RETRY
Used when the film fails to be loaded. (Refer to 
CAUTION
Do not use this mode under the normal operation
as the number of films in the tray resets to 0.
14
POWER SAVE
Sets the power saving function of the device. (Refer to 
CAUTION
The print data from the diagnostic device cannot be received or printing cannot be made in the
maintenance mode. The print data queued for printing will be printed out after the device exits