IBM RS/6000 44P Manual Do Utilizador

Página de 216
a
Acknowledge an error
b
Back one page
c
Toggle between cycle count and last error
e
View the AIX error log
f
Page forward one page
q
Return to Main Menu
r
Refresh screen
s
Enable or disable beep on error
x
Exit system exerciser
Acronyms
The following list describes abbreviations used in the exerciser reports. To toggle
between two states for (example, Activate/Halt Devices), use the number of the device.
Acronym
Description
COE
Continue on error (use number to select.
CP
Device has run the specified number of cycles and is not running
DD
Exerciser has been terminated by a signal
ER
Device has stopped with an error
HG
Device is hung
HOE
Halt on error (use number to select)
RN
Device is running
ST
Device is stopped
Memory Exerciser
The memory exercisers are labeled
memx
, where x is a number for the exerciser.
Multiple exercisers can be active.
The memory exerciser requests as many memory buffers as possible from AIX. The
exerciser then fills the memory buffers with specified bit patterns, then reads and
compares the memory buffers to the specified bit patterns.
On systems with multiple processors, a process is started for each processor. The free
memory space is split evenly between the available processors, thus reducing the time
required to exercise all of the memory.
If the system is working properly, no comparison errors are produced. If a
nonrecoverable memory error occurs, the system crashes. Recoverable memory errors
are logged by the AIX operating system.
The following items must be available to run this service aid:
v
Online diagnostics loaded in maintenance mode
v
128 KB of free space in /etc/lpp/diagnostics/data
v
The following commands must be available:
– vmstat
– lsps
– bootinfo
Chapter 6. Introducing Tasks and Service Aids