IBM 1116 Manual Do Utilizador

Página de 120
Argecy Computer Corporation 248-324-1800
84
For entry and standard models, Parallel Strobe Adjust is set to Off (0), the 
factory default.
This setting lets you increase the amount of time strobe is sampled to 
determine that valid data is available on the parallel port.
• Press the operator panel button with a brief button press to scroll 
through the settings (Off=0, On=+1, Auto=+2). Press the operator panel 
button with a long button press to select and save the On or Auto 
setting. As the setting is saved, all operator panel lights remain on for 
approximately 2 seconds
• Press the operator panel button with a double button press to scroll to 
the next menu item, USB Port Enabled.
Turn off the printer to exit the advanced troubleshooting mode.
USB Port Enabled is set to Auto, the factory default.
The Universal Serial Bus (USB) cable lets you connect a variety of 
devices to your computer with a single cable.
• Press the operator panel button with a brief button press to scroll 
through the settings (Off, On, Auto). Press the operator panel button 
with a long button press to select and save the Off or On setting. As the 
setting is saved, all operator panel lights remain on for approximately 2 
seconds
• Press the operator panel button with a double button press to scroll to 
the next menu item, USB NPA Mode.
Turn off the printer to exit the advanced troubleshooting mode.
This light sequence in 
advanced troubleshooting 
mode:
Corresponds to this setting: