Psion Teklogix PX750 Manual Do Utilizador

Página de 238
150
Psion Teklogix NEO Hand-Held Computer User Manual
Chapter 5: Configuration
Decoded (Internal) Scanners
Transmit Check Digit
If this parameter is enabled, the check digit is included with the bar code data.
Convert To EAN 13
If this parameter is enabled, the I 2 of 5 bar code is converted to EAN 13.
Length Restriction
Refer to “Length Restriction” on page 142 for details. 
Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details. 
5.13.2.15 Discrete 2 of 5
Enabled
Set this parameter to on to enable “Discrete 2 of 5”.
Set Length L1 And Set Length L2
Lengths for “Discrete 2 of 5” can be set for Any lengthLength within a rangeOne discrete 
length
 or Two discrete lengths. The length of a code refers to the number of characters (i.e., 
human readable characters), including check digit(s). 
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where 
you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a selected 
length. Choosing Two discrete lengths allows you to decode only those codes containing two 
selected lengths. Length within a range allows you to decode a code type within a specified 
range from 1 to 12.
Length Restriction
Refer to “Length Restriction” on page 142 for details. 
Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details.