Psion Teklogix PX750 Manual Do Utilizador

Página de 238
Psion Teklogix NEO Hand-Held Computer User Manual
163
Chapter 5: Configuration
Decoded (ISCP)
Matrix 2 of 5
Length Restriction
Refer to “Length Restriction” on page 142 for details. 
Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details. 
5.13.3.15 Matrix 2 of 5
Enabled
Set this parameter to on to enable “Matrix 2 of 5”.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to 
the number of characters (i.e., human readable characters), including check digit(s). 
Length Restriction
Refer to “Length Restriction” on page 142 for details. 
Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details. 
5.13.3.16 Discrete 2 of 5
Enabled
Set this parameter to on to enable “Discrete 2 of 5”.
Standard 2 of 5 Format
This parameter allows you to choose a standard format – either Identicon (6 start/stop bars) 
or Computer Identics (4 start/stop bars).
Check Digit Verification
The available options for this parameter are Disabled and MOD 10 Check. “Check Digit 
Verification” uses the specified algorithm of the option you've chosen to ensure the integrity 
of the symbol data before transmitting. If the data does not contain that algorithm, the data is 
not transmitted. 
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.