3  Tests and Diagnostics 
3.20  Log Utilities 
3.20.2 Operations 
1. Selecting 
5
 and pressing 
Enter 
in the DIAGNOSTIC MENU, logs error information 
into RAM or onto a floppy disk. The error information is displayed in the following 
format: 
XXXXX ERRORS 
CNT TS-NO  PASS 
STS ADDR 
  WD 
RD HSTS [ERROR STATUS NAME] 
 
001  FDD 02  0000 103  00001  00 00 0000 FDD-WRITE PROTECTED 
001 FDD 
01  0000  180  00001 00 
00 0000 FDD-TIME OUT ERROR 
 
Error count 
Pass count 
Error status 
Address 
Subtest number 
Test name 
 
 
 
 
 
 
 
 
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]] 
2.  The error information displayed on the screen can be manipulated by the following 
number keys: 
The 
1
 key scrolls the display to the next page. 
The 
2
 key scrolls the display to the previous page. 
The 
3
 key returns to the Diagnostic Menu. 
The 
4
 key erases all error log information in RAM. 
The 
5
 key outputs the error log information to a printer. 
The 
6
 key reads the log information from a floppy disk. 
The 
7
 key writes the log information to a floppy disk. 
3.  In the case of “error retry OK,” a capital “R” will be placed at the beginning of the 
error status. However, it is not added to the error count. 
Error status name 
Read data 
Write data 
HDC status 
3-40 
 
Satellite M30-35 Maintenance Manual (960-455)