Toshiba PROL450D Manual Do Utilizador

Página de 227
2 Troubleshooting Procedures 
Satellite L450D/455D, Satellite pro L450D Series Maintenance Manual 
 
                                                                    
 39
 
Procedure 2:  CRT set check 
Procedure 1 
CRT connection check 
The CRT cable may be damaged or the connections may be loose. Perform Check 1: 
Check 1 
Make sure CRT cable is firmly plugged into both the CRT set and the CRT port 
of the computer. If the cable is connected correctly, go to Check 2. 
Check 2 
Make sure the CRT port is firmly secured to the system board of the computer. If 
the malfunction remains, go to Check 3. 
Check 3 
The CRT cable may be damaged. Replace with a good cable. If the malfunction 
remains, go to Procedure 2. 
Procedure 2 
CRT set check 
The CRT set may be faulty. Perform Check 1: 
Check 1 
Try using the set for CRT reception. If it does not work, the set may be damaged. 
If the set does work, perform Check 2. 
Check 2 
Try connecting a different CRT to the computer. If the replacement CRT works, 
the original set may be damaged. If the replacement set does not work the system 
board may be damaged. Replace it with a new one following the instructions in 
Chapter 4.