1  Hardware Overview 
TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813)  [CONFIDENTIAL] 
1-33 
1.9.2 
Battery Charging Control 
Battery charging is controlled by a power supply microprocessor. The microprocessor 
controls whether the charge is on or off and detects a full charge when the AC adaptor and 
battery are attached to the computer.  The system charges the battery. 
Battery Charge 
When the AC adaptor is attached, there are two types of charge: When the system is powered 
off and when the system is powered on. Table 1-10 lists the charging time required for 
charges. 
Table 1-9  Time required for charges 
Battery type 
Power on (hours) Power 
off 
(hours) 
Battery(48Wh, 6 cell) 
about 3.0 to 10.5 
About 2.5  
Battery(55Wh, 6 cell) 
About 4.0to 12.0  
About 2.5 
NOTE:  The time required when the system is powered on is affected by the amount of 
power the system is consuming.  Use of the fluorescent lamp and frequent disk 
access diverts power and lengthens the charge time. 
If any of the following occurs, the battery charge process stops.  
1.  The battery becomes fully charged.  
2.  The AC adaptor or battery is removed.  