Toshiba S500M Manual Do Utilizador

Página de 477
   
  Troubleshooting Procedures  
TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813) [CONFIDENTIAL] 
2-37 
2.6.4  Procedure 4 Diagnostic Test Program Execution Check 
The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the 
Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more information about 
the HDD test program. 
If an error is detected during the HDD test, an error code and status will be displayed. The 
error codes and statuses are described in Table 2-8. If an error code is not displayed but the 
problem still occurs, go to Procedure 5. 
Table 2-6  2.5” Hard disk drive error code and status 
Code Status 
05 
HDD - HDC NOT RESET ERROR 
07 
HDD - DRIVE NOT INITIALIZE 
09 
HDD - DMA BOUNDARY ERROR 
0B 
HDD - BAD TRACK ERROR 
BB 
HDD - UNDEFINED ERROR 
08 
HDD - OVERRUN ERROR (DRQ ON) 
01 
HDD - BAD COMMAND ERROR 
02 
HDD - ADDRESS MARK NOT FOUND 
04 
HDD - RECORD NOT FOUND ERROR 
10 
HDD - ECC ERROR 
20 
HDD - HDC ERROR 
40 
HDD - SEEK ERROR 
80 
HDD - TIME OUT ERROR 
11 
HDD - ECC RECOVER ENABLE 
AA 
HDD - DRIVE NOT READY 
CC 
HDD - WRITE FAULT 
E0 
HDD - STATUS ERROR 
0A 
HDD - BAD SECTOR 
EE 
HDD - ACCESS TIME ERROR 
DA 
HDD - NO HDD 
12 
HDD - DMA CRC ERROR