3  Diagnostic Programs 
 
3.9 Communication 
48 
TECRA S1Maintenance Manual 
3.9 Communication 
(COMM) 
Subtest 01 
 LPT  
This test item is to check whether there is open or short circuit issue in the external 
pins by looping back the external pins, controlling the voltage of each data pin, 
control pin and status pin. 
The test requires an external connector to insert into the tested LPT port. Below is the 
connector's description. 
Fixture Description: 
 
 
 
 
 
 
 
 
Note:  (1)~(17) -------- Pin number 
PD0~ PD7--------Data Line  
 Status Line --------  –ERROR(S3), +SELECT(S4), –ACK(S6), +PE(S5), +BUSY(S7) 
Control Line--------  –AUTFD(C1), –PINIT(C2), -STROBE(C0), –SLIN(C3) 
1. Register Check 
Check whether the data register and control register works normally. 
2. IRQ Check 
Check whether LPT interrupt works normally. 
3.  External Loop back 
Check whether there is open or short circuit issue. 
4. ECP Mode 
(9) + PD7 
(15) -ERROR 
(5) + PD3 
(1)  - STROBE 
(10)  - ACK 
(8) + PD6 
(14) -AUTFD 
(7) + PD5 
(13)
(6) + PD4 
(16) -PINIT 
(2) +PD0 
(11)+ BUSY 
(3) + PD1 
(17)  - SLIN 
(4) + PD2 
(12) + PE