3.9 Communication 
3  Diagnostic Programs 
TECRA S1Maintenance Manual 
51 
Stop Bit: Choose the stop bit; 
Word Size: Choose the bit number in one word; 
Baud Start/End: Select the start baud rate and end baud rate.All the baud rates 
between the start and end baud rate would be tested in the test. 
4.  External Loop back 
This test item is to check whether there is no open circuit issue in the COM port. 
The parameter dialog window is the same as that in ‘3. Internal Loop back’. 
5. FIFO Test 
Check whether FIFO works normally. 
The parameter dialog window is the same as that in ‘2. IRQ Check’. 
6. Parity Check 
Verify whether the parity check in the COM port works normally. 
7.  Stop Bits Check 
Verify whether the stop bits check in the COM port works normally. 
8.  Word Length Check 
Verify whether the word length check in the COM port works normally. 
Subtest 03    IrDA 
This test item is divided into Fast IR (FIR) and Slow IR (SIR). FIR supports the 
transfer rates of 0.576Mbps, 1.152Mbps and 4.000Mbps; SIR supports the transfer 
rates of 2400bps, 4800bps, 9600bps, 19200bps, 38400bps, 57600bps, and 115200bps. 
The unit under testing (UUT) is called Slave, that requires a unit whose IrDA works 
normally(that is called Master) for transferring data between Slave and Master. Below 
is the parameter dialog window of IrDA test.