Toshiba TECRA S1 Manual Do Utilizador

Página de 268
3  Diagnostic Programs                                                                       3.11Error Codes and Description 
66 
TECRA S1Maintenance Manual 
 05 
Seek Error 
HD is damaged. 
As above. 
 06 
Disk Controller Self Test 
Failed 
The HD controller is damaged.  As above. 
 07 
Disk Controller Test 
unexpected interrupt 
Failed 
The HD controller is damaged.  As above. 
 09 
Disk Controller action 
Test Failed 
The HD controller is damaged.  As above. 
 10 
Disk dos not support 
SMART 
Disk dos not support SMART 
Change HD which supported 
SMART and test again    
 11 
Disk read attribute 
threshold error 
Disk read attribute threshold 
error 
Send the HD for repair. 
 12 
Disk read attribute value 
error 
Disk read attribute value error 
As above. 
 13 
Disk SMART attribute 
value error 
Disk SMART attribute value 
error 
As above. 
21xx  
IDE-CDROM 
 
 
 01 
No Disk in CDROM 
No disk is found in the CD-
ROM. 
Insert a disk into the CD-ROM. 
 02 
The Disk in CDROM is 
not Data Disk 
The disk in the CD-ROM is not 
Data Disk. 
Insert a DATA CD. 
 03 
IDE-CD Controller Error  Functional errors with the CD-
ROM. 
Send the CD-ROM for repair. 
 04 
CD Read Error 
Either the disk or the CD-ROM 
is damaged. 
Replace the disk or send the CD-
ROM for repair. 
 05 
The Disk in CDROM is 
not Audio-CD 
The disk in the CD-ROM is not 
Audio-CD. 
Insert an Audio-CD. 
 06 
Audio-CD Play Error 
Errors with the Audio-CD 
playing. 
Replace the Audio-CD or send 
the CD-ROM for repair. 
 07 
CD Seek Error 
Either the disk or the CD-ROM 
is damaged. 
Replace the disk or send the CD-
ROM for repair. 
 08 
The Disk in CDROM is 
not CD-RW 
The Disk in CDROM is not CD-
RW 
Replace a CD-RW disk with 
Direct CD format or send the CD-
ROM for repair. 
 09 
Eject Error 
Wrong CD-ROM drive. 
Exit from the wrong drive.