Toshiba TECRA S1 Manual Do Utilizador

Página de 268
2  Troubleshooting 
2.3  Power Supply 
2-8 
TECRA S1  Maintenance Manual 
Procedure 2  Connection Check 
Power is supplied to the system board as illustrated below:  
AC
adaptor
System board
AC power cord
AC adaptor cord
Battery pack
 
 
Follow the steps below to check whether each connector has been connected correctly:  
Check 1 
Make sure the AC adaptor and AC power cord have been firmly plugged into 
the DC IN 15V socket and wall outlet, respectively.  When they have been 
connected correctly, perform Check 2. 
Check 2 
Connect a new AC adaptor and AC power cord. 
•  If the DC IN LED does not go on, go to Procedure 3. 
•  If the battery LED does not go on, perform Check 3. 
Check 3 
Make sure the battery pack has been correctly installed in the computer. If the 
battery LED does not go on while the battery pack has been installed correctly, 
go to Procedure 3.