2  Troubleshooting 
2.3  Power Supply 
Procedure 2  Connection Check 
Power is supplied to the system board as illustrated below:  
AC
adaptor
System board
AC power cord
AC adaptor cord
Battery pack
 
 
Follow the steps below to check whether each connector has been connected correctly:  
Check 1 
Make sure the AC adaptor and AC power cord have been firmly plugged 
into the DC IN socket and wall outlet, respectively.  When they have been 
connected correctly, perform Check 2. 
Check 2 
Connect a new AC adaptor and AC power cord. 
•  If the DC IN LED does not go on, go to Procedure 3. 
•  If the battery LED does not go on, perform Check 3. 
Check 3 
Make sure the battery pack has been correctly installed in the computer. 
If the battery LED does not go on while the battery pack has been installed 
correctly, go to Procedure 3. 
Procedure 3  Replacement Check 
The system board, power supply board, or CPU may be faulty.  Disassemble the computer 
according to Chapter 4 and follow the steps below:  
 
Check 1 
Replace the power supply board with a new one.  If the battery pack is still 
not working properly, perform Check 2. 
 
Check 2 
Replace the system board with a new one.  If the battery pack is still not 
working properly, perform Check 3. 
 
Check 3 
Replace the CPU with a new one.
2-8 
Satellite A300/Satellite Pro A300/EQUIUM A300/SATEGO A300   Maintenance Manual