2.3  Power Supply Troubleshooting 
2  Troubleshooting Procedures 
Tecra A3/S2 Series Maintenance Manual 
2-9 
Table 2-2  DC-IN LED 
AC-IN LED 
Power supply status  
Solid on 
AC power exists (LED  is solid green). 
Off 
No AC power exists. 
 
To check the power supply status, install a battery pack and connect an AC adaptor to the DC-IN 
port on the computer and to a power supply. 
If the DC-IN LED or Battery LED  is not lit, go to Procedure 2. 
 
Procedure 2 
Adaptor / battery replacement 
A faulty adaptor may not supply power or may not charge the battery. Perform Check 1. 
Check 1 
Connect a new AC adaptor. If the problem is not resolved, go to Check 2. 
Check 2 
Insert a new battery. If the problem is still not resolved, go to Procedure 3.