3.7  Memory Test 
To execute the Memory Test, select 2 from the DIAGNOSTIC TEST MENU, press Enter 
and follow the directions on the screen. Move the highlight bar to the subtest you want to 
execute and press Enter
Subtest 01 
Conventional memory 
This subtest writes a constant data to conventional memory (0 to 640 KB), 
then reads the new data and compares the result with the original data.  
Subtest 02 
Protected Mode  
NOTE: The CONFIG.SYS file must be configured without expanded memory manager 
programs such as EMM386.EXE, EMM386.SYS or QEMM386.SYS. Also, the 
HIMEM.SYS must be deleted from the CONFIG.SYS file. 
This subtest writes constant data and address data (from 1MB to maximum 
MB), and reads the new data and compares the result with the original data.  
Subtest 03 
Cache memory (on/off) 
To test the cache memory, a pass-through write-read comparison of ‘5Ah’ 
data is run repeatedly to the test area (‘7000’: ‘Program’ size to ‘7000’: 
‘7FFF’ (32 KB)) to check the hit-miss ratio (on/off status) for CPU cache 
memory. One test takes 3 seconds.  
Number of misses 
 Number of hits  OK 
Number of misses 
 Number of hits  Fail 
Subtest 04 
Stress 
Write/Read buffer (1 size = B30h) is prepared in the conventional memory. 
The data is made in the Write Buffer, the data in Write Buffer is written in the 
area of address of 1MB or after. The data is red in the Read Buffer and data is 
compared in area up to the maximum size. 
Data:  FFh, FFh, FFh, FFh, FFh, 00h, 00h, 00h, 00h, 
FFh, FFh, FFh, 00h, FFh, 00h, 00h, FFh, 00h, 
00h, FFh, FFh, FFh, FFh, 00h, 00h, 00h, AAh