3.2  Executing the Diagnostic Test 
3 Tests and Diagnostics 
4.  Select the option you want to execute and press 
Enter
. When you  select 1- 
SYSTEM TEST, the following message will appear: 
SYSTEM TEST NAME    XXXXXXX 
xxxxxxx DIAGNOSTIC TEST VX.XX 
[Ctrl]+[Break] ; test end 
[Ctrl]+[C]     ; key stop 
SUB-TEST  : 
XX 
PASS COUNT : XXXXX     ERROR COUNT: XXXXX 
WRITE DATA : XX        READ DATA  : XX 
ADDRESS   : XXXXXX 
  STATUS  : 
XXX 
SUB-TEST MENU : 
01 - ROM checksum 
02 - Geyserville 
03 -  
04 – Fan ON/OFF 
05 - Thermister Check 
06 - Quick charge 
07 - DMI read 
08 - DMI write 
09 -  
10 - CPU Temperature 
11 – Wake Up Check  
99 - Exit to DIAGNOSTIC TEST MENU 
 
NOTE: The menu displayed by your computer may be slightly different from the one 
shown above. 
5.  Select the desired subtest number from the subtest menu and press 
Enter
. The 
following message will appear: 
TEST LOOP  : YES (or NO) 
ERROR STOP : YES (or NO) 
Use the right and left arrow keys to move the cursor to the desired option. 
Selecting 
YES 
of TEST LOOP
 
increases the pass counter by one, each time the test 
cycle ends and restarts the test cycle.  
Selecting 
NO 
returns the process to the subtest menu after the test is complete. 