1  Hardware Overview 
1.13  Batteries 
 
1.13.2 Battery Charging Control 
Battery charging is controlled by a power supply microprocessor. The power supply 
microprocessor controls power supply and detects a full charge when the AC adaptor and 
battery are connected to the computer. 
 Battery Charge 
When the AC adapter is connected, normal charging is used while the system is 
turned on, and quick charge is used while the system is turned off or in suspend mode. 
Table 1-14 shows the time required for charges of main battery. 
Table 1-14 Time required for charges of main battery 
Condition Charging 
Time 
3,600mAh 
About 3.5 to 9 hours or longer 
Normal charge 
4,400mAh 
About 4 to 12 hours or longer 
3,600mAh 
About 2.6 hours 
Quick charge 
4,400mAh 
About 2.6 hours 
 
Charge is stopped in the following cases. 
  1. The main battery is fully charged 
  2. The main battery is removed 
  3. Main battery or AC adapter voltage is abnormal 
  4. Charging current is abnormal 
 Data preservation time  
When turning off the power in being charged fully, the preservation time is as 
follows: 
Table 1-15 Data preservation time 
Condition Preservation 
time 
3,600mAh 
About 3 days 
Standby Mode 
4,400mAh 
About 3.6 days 
3,600mAh 
About 25 days 
Boot Mode 
4,400mAh 
About 30 days 
 
1-28 