IBM 6269 Manual Do Utilizador
If the printer self-test does not run correctly, the problem is in the printer.
Refer to the printer service manual.
Refer to the printer service manual.
If the printer self-test runs correctly, install a wrap plug in the parallel port
and run the diagnostic tests to determine which FRU failed.
and run the diagnostic tests to determine which FRU failed.
If the diagnostic tests (with the wrap plug installed) do not detect a failure,
replace the printer cable. If that does not correct the problem, replace the
system board or adapter connected to the printer cable.
replace the printer cable. If that does not correct the problem, replace the
system board or adapter connected to the printer cable.
Power supply
If the power-on indicator is not on, the power supply fan is not running, or
the computer will not power-off, use the following procedures.
the computer will not power-off, use the following procedures.
Check/Verify
FRU/Action
Verify that the voltage-selector switch is set for the
correct voltage.
correct voltage.
Correct the voltage-selector switch setting
Check the following for proper installation.
v Power Cord
v On/Off Switch connector
v On/Off Switch Power Supply connector
v System Board Power Supply connectors
v Microprocessor(s) connection
v Power Cord
v On/Off Switch connector
v On/Off Switch Power Supply connector
v System Board Power Supply connectors
v Microprocessor(s) connection
Reseat
Check the power-on switch for continuity.
Power Cord
Check the power-on switch for continuity.
Power-on Switch
If the above are correct, check the following voltages.
108
Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,