Using the Switch Data Ports
You also can configure in-band management through any of the switch data ports. To allow in-band
management, use the following procedure:
management, use the following procedure:
1.
Log on to the switch.
2.
Enter IP interface mode.
Note –
Interface 125 through 128 are reserved for out-of-band management interfaces (see
).
3.
Configure the management IP interface/mask.
Using IPv4:
Using IPv6:
4.
Configure the VLAN, and enable the interface.
5.
Configure the default gateway.
If using IPv4:
If using IPv6:
RS G8124> enable
RS G8124# configure terminal
RS G8124(config)# interface ip
<IP interface number>
RS G8124(config-ip-if)# ip address
<management interface IPv4 address>
RS G8124(config-ip-if)# ip netmask
<IPv4 subnet mask>
RS G8124(config-ip-if)# ipv6 address
<management interface IPv6 address>
RS G8124(config-ip-if)# ipv6 prefixlen
<IPv6 prefix length>
RS G8124(config-ip-if)# vlan 1
RS G8124(config-ip-if)# enable
RS G8124(config-ip-if)# exit
RS G8124(config)# ip gateway
<gateway number>
address
<IPv4 address>
RS G8124(config)# ip gateway
<gateway number>
enable
RS G8124(config)# ip gateway6
<gateway number>
address
<IPv6 address>
RS G8124(config)# ip gateway6
<gateway number>