Advantech AWS-8248 Manual Do Utilizador
AWS-8248 User’s Manual
50
Reset time:
When the power supply has automatically shut down, and the short cir-
cuit, over-current and/or over-voltage conditions have ceased to exist,
power will be automatically recycled to restart the power supply within 3
seconds of such return to normal conditions.
cuit, over-current and/or over-voltage conditions have ceased to exist,
power will be automatically recycled to restart the power supply within 3
seconds of such return to normal conditions.
No load start:
When the power supply is switched on but with no load connected, the
power supply does not get damaged, and it is still completely safe for
users.
power supply does not get damaged, and it is still completely safe for
users.
Transient response:
Dynamic load change: ±50% of maximum rating load
Recovery time: 500
µs max.
Reliability:
Mean time between failures (MTBF):100,000 hours minimum
Operating temperature:
0 ~ 50° C
Storage temperature:
-40 ~ 60° C
Operating and storage humidity:10 ~ 95% RH
Operating altitude:
sea level ~ 15,000 ft
Storage altitude:
sea level ~ 50,000 ft
International Standards Compliance
Safety:
UL 1950
CSA 22.2 No. 234
TUV EN 60950
CSA 22.2 No. 234
TUV EN 60950
EMI:
FCC Part 15 Subpart J Class B