Emerson ATCA-7150 Manual Do Utilizador

Página de 122
   
Installation of the RTM-ATCA-7150
ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)
36
3. Remove the desiccant bag shipped together with the blade and dispose of it
according to your country’s legislation.
2.3
Environmental and Power Requirements
The following environmental and power requirements are applicable to the board. 
2.3.1
Environmental Requirements
The product is thoroughly inspected before shipment. If any damage occurred during 
transportation or any items are missing, please contact our customer's service immediately.
Table 2-1 Environmental Requirements RTM-ATCA-7150
Requirement
Operating
Non-Operating
Temperature
+5ºC (41ºF) to +40ºC (104ºF) (normal operation) 
according to NEBS Standard GR-63-CORE
-5ºC to +55ºC (short term operation) according 
to NEBS Standard GR-63-CORE
-40ºC (-40ºF) to +70ºC 
(158ºF) (may be further 
limited by installed 
accessories) 
Temp. Change
+/- 0.25ºC/min or 15ºC/h (59ºF/h) according to 
NEBS Standard GR-63-CORE
 +/- 0.25ºC/min or 15ºC/h 
(59ºF/h)
Rel. Humidity
5% to 85% non-condensing according to 
Emerson Network Power Embedded 
Computing-internal environmental 
requirements
5% to 85% non-condensing 
according to Emerson 
Network Power Embedded 
Computing-internal 
environmental 
requirements
Altitude
<= 4000m