Electronic Thermal Overload Alarm Setting
The thermal overload detection protects the 
inverter and motor from overheating due to 
an excessive load. It uses a current/inverse 
time curve to determine the trip point.
First, use B013 to select the torque charac-
teristic that matches your load. This allows 
the inverter to utilize the best thermal 
overload characteristic for your application.
The torque developed in a motor is directly 
proportional to the current in the windings, 
which is also proportional to the heat generated (and temperature, over time). Therefore, 
you must set the thermal overload threshold in terms of current (amperes) for parameter 
B012. The range is 20% to 120% of the rated current for each inverter model. If the 
current exceeds the level you specify, the inverter will trip and log an event (error E05) in 
the history table. The inverter turns the motor output OFF when tripped. Separate 
settings are available for the second motor (if applicable) as shown in the following 
table.
Output frequency
Constant torque
Reduced
torque
B013 = 01
B013 = 00
Torque
5
20
60
120
Hz
100%
80%
60%
0
“B” Function
Run 
Mode 
Edit
Lo Hi
Defaults
Func.
Code
Name /
SRW Display
Description
–FE(F) 
(EU)
–FU 
(USA)
Units
B012 Level of electronic 
thermal setting
Set a level between 20% and 
120% for the rated inverter 
current.
✘ ✔
Rated current 
for each inverter 
model *1
A
E-THM LVL001.60A
B212 Level of electronic 
thermal setting, 2nd 
motor
Set a level between 20% and 
120% for the rated inverter 
current.
✘ ✔
Rated current 
for each inverter 
model *1
A
2ETHM LVL 01.60A
B013 Electronic thermal 
characteristic
Select from two curves, option 
codes:
00 .. Reduced torque 1
01 .. Constant torque
02 .. Reduced torque 2
✘ ✔
01
01
E-THM CHAR  CRT
B213 Electronic thermal 
characteristic, 2nd 
motor
Select from two curves, option 
codes:
00 .. Reduced torque 1
01 .. Constant torque
02 .. Reduced torque 2
✘ ✔
01
01
2ETHM CHAR  CRT