Fluke 1744 Manual Do Utilizador

Página de 73
 
Power Quality Logger 
 Technical 
Specifications 
 
  
49 
Power Supply 
Functional range 
88 to 660 V RMS ac absolute, 50 Hz / 60 Hz 
Safety 
EN 61010-1 600 V CAT III, 300 V CAT IV, 
pollution degree 2, double insulation 
Fuse 
Power supply fuse can be replaced only in service 
facility. Supply can be connected in parallel to 
measuring inputs (up to 660 V RMS ac). 
Power consumption 
5 W 
Memory capacity 
8 MB Flash-EPROM 
Intervals 
> 5.600 intervals, > 39 days with 10-min intervals 
Events > 
13.000 
Memory model 
Linear, circular 
Interface 
RS232, 9600 to 115000 Baud, automatic selection,  
3-wire communication. 
Dimensions 
170 mm x 125 mm x 55 mm 
Weight 
Approx. 0.9 kg 
Measurement 
A/D converter 
16 bit 
Sampling frequency 
10.24 kHz 
Anti-aliasing filter 
FIR-Filter, f
C
 = 4.9 kHz 
Frequency response 
Uncertainty < 1% of Vm for 40 to 2500 Hz 
Interval length 
1, 3, 5, 10, or 30 seconds, 
1, 5, 10, 15, or 60 minutes 
Averaging time for 
min/max values 
½ , 1 line power period 
200 ms 
1, 3, 5 s 
Time base 
Resolution: 10 ms (at 50 Hz) deviation: 2 s/day  
at 23 °C.