Fluke 1744 Manual Do Utilizador

Página de 73
 
Power Quality Logger 
 Technical 
Specifications 
 
  
53 
Power (Logging Functions A, P only) P, S, |P| 
Active power P 
As per EN 61036, class 2 
Distorting power D 
As per EN 61268, class 2 (A-version only) 
Max value 
Highest value per interval 
Min value 
Smallest value per interval 
Phase uncertainty 
< 0.3 degrees 
Conditions Conductor 
centered 
within clamp jaws or 
Flexi Set 
Harmonics 
V
m
, I
m
, THDV, THDI per IEC/EN 61000-4-7, class B 
Voltage harmonics (function A) 
intrinsic uncertainty: 
For V
< 3% V
N
: < 0.15% V
N
 
For V
m
 ≥ 3% V
N
: < 5% V
m
 
Current harmonics (function A) 
intrinsic uncertainty 
For I
m
 < 10% I
N
: < 0.5% I
N
 
For I
m
 ≥ 10% I
N
: < 5% I
m
 
THDV (function A) intrinsic 
uncertainty at V
N
 
For THDV < 3%: < 0.15% 
For THDV ≥ 3%: < 5% 
THDV (function P) intrinsic uncertainty
at V
N
 
For THDV < 3%: < 1%  
For THDV ≥3%: < 5% 
THDI (functions A, P) intrinsic 
uncertainty at I
I
 
For THDI < 3%: < 2% 
For THDI ≥ 3%: < 5% 
Statistics 
Frequency 
42 classes for 10 s mean values 
Ripple-control signals 
Interharmonics 
21 classes for 3 s mean values 
Analysis of logging data 
Programming and analysis is done by PQ Log software on PC.