HSM CMN4000R Manual Do Utilizador
T H E C O N T I N U O U S P O W E R C O M P A N Y
Page 13
SPECIFICATIONS
ELECTRICAL
Input CMN3000R/CMN4000R
Voltage
120V +10%, -20% (without
Battery discharge)
Battery discharge)
Power Factor Corrected
IAW MIL STD. 1399 Sec. 300
Frequency
45 to 65Hz
Current(Amps) @ 120VAC
21A/28A @ 100% Non-Linear
Output
Voltage
120VAC
± 3%
Frequency
50Hz / 60Hz (software select)
Line Sync (software select)
Line Sync (software select)
Current(Amps)
25A/33A @ 100% Non-Linear
Crest Factor Ratio
(Non-linear load and
less than 5% THD) Typical
(Non-linear load and
less than 5% THD) Typical
@50% Load Up to 4.8:1
@75% Load Up to 3.2:1
@100% Load Up to 2.4:1
@75% Load Up to 3.2:1
@100% Load Up to 2.4:1
Total Harmonic Distortion (THD)
3% Typ; 5% Max.
(@100% Non-linear load)
(@100% Non-linear load)
Dynamic Response
±4% for 100% Step Load Change,
0.5 Millisecond Recovery Time
0.5 Millisecond Recovery Time
Overload
110% for 10 Minutes;
200% for 50 Milliseconds
200% for 50 Milliseconds
Efficiency (UPS)
85-87% Typical
UPS Protection
Input and Output Short Circuit;
Input and Output Overload;
Excessive Battery Discharge
Input and Output Overload;
Excessive Battery Discharge
ENVIRONMENTAL
Operating Temperature
0
o
C to 40
o
C
Humidity
0% to 95% Non-condensing
Altitude
Sea Level to 10,000 Feet
Audible Noise
42 dBA at Five Feet
MECHANICAL
Input
CPC Type 3 Position Inlet
Connectors
Connectors
Output (Qty.)
Load 1 and Load 2 (3 each)
NEMA Type 5-20R
NEMA Type 5-20R
Cooling
Low Velocity, Temperature
Controlled Reversible Forced
Air
Controlled Reversible Forced
Air
Dimensions: HxWXD In.
5.25 x 19 x 23
Weight: Lbs. (Kg)
85 (38.8)
DESIGN
Standard Features
Power Factor Corrected, Digital
Regenerative
™ On-Line, Sinewave
Inverter Powers Load Continuously
Extended Brownout Protection
Designed for Non-linear Loads
Continuous Operation on
Extended Brownout Protection
Designed for Non-linear Loads
Continuous Operation on
-25%,+12% Line
Automatic Bypass
RS232 Data Interface
Software Selectable Output
RS232 Data Interface
Software Selectable Output
Frequency
AC Output Switch
Auxiliary Battery Connector
Rear Mounted Ground Stud
Optional SNMP Interface
Auxiliary Battery Connector
Rear Mounted Ground Stud
Optional SNMP Interface
Specifications
UL 1778, CUL, FCC Class A,
IEEE 587/ANSI C62.41,
IEC 555 @ 120VAC
IEEE 587/ANSI C62.41,
IEC 555 @ 120VAC
MTBF
In Excess of 100,000 Hours
CONTROLS AND INDICATORS
Visual Indicators
Sequenced LEDs
Single LED
Battery Level, Load Level
AC Input, Inverter On, Load On
Summary Alarm, Alarm Silence,
Cold Start,
Summary Alarm, Alarm Silence,
Cold Start,
Front Panel Controls
Power On, Cold Start
Alarm Silence, Battery Test
AC Output On/Off, Bypass
Alarm Silence, Battery Test
AC Output On/Off, Bypass
Audible Alarms
Utility Interrupt, Inverter Failure
Overload, Low Battery
Overload, Low Battery
RS232 Data Interface (DB-9F)
Full Interactive, Remote Computer
Monitoring and Control of UPS
Functions.
Monitoring and Control of UPS
Functions.
Compatible with Systems
Enhancement
Enhancement
TM
UPS Monitor &
Control Software
Open Collector (DB-9F)
Allows Alarm Function Monitoring
Optional SNMP Interface
(RJ45 or BNC)
Allows Full Control and Monitoring
Over Network Connection.