Panasonic PT-DW5000 Manual Do Utilizador

Página de 12
52
FAN ERROR 5
LAMP4 FAN
Normal fan operation
51
FAN ERROR 4
LAMP3 FAN
50
FAN ERROR 3
LAMP2 FAN
49
FAN ERROR 2
LAMP1 FAN
48
FAN ERROR 1
P-UNIT FAN
47
46
45
44
43
42
41
40
39
38
37
CHANGE INTERNAL CLOCK BATTERY
Date/time is invalid (before Jan. 1, 2006 or Jan. 1, 2036 or later).
Date/time reset (after battery change)
36
FILTER CLOGGED ERROR
35
AIR VOLUME SENSOR NOT FOUND
The air volume sensor is not found.
Main power on
34
OUTPUT AIR SENSOR NOT FOUND
The output air sensor is not found.
33
DMD SENSOR NOT FOUND
The DMD sensor is not found.
32
INPUT AIR SENSOR NOT FOUND
The input air sensor is not found.
29
LAMP COVER NOT CLOSED
The lamp cover is not closed (for more than 1 second continuously).
Lamp cover closed, then main power on
28
AC VOLTAGE DROP WARNING (BELOW 90 V)
27
LAMP 4 NOT MOUNTED
The lamp is not mounted.
Lamp mounted, then main power on
26
LAMP 3 NOT MOUNTED
25
LAMP 2 NOT MOUNTED
24
LAMP 1 NOT MOUNTED
23
LAMP 4 IGNITIONFAILURE
The lamp fails to ignite.
Lamp illumination processing performed
22
LAMP 3 IGNITIONFAILURE
21
LAMP 2 IGNITIONFAILURE
20
LAMP 1 IGNITIONFAILURE
19
LAMP 4 ILLUMINATION FAILURE
The lamp fails to illuminate.
18
LAMP 3 ILLUMINATION FAILURE
17
LAMP 2 ILLUMINATION FAILURE
16
LAMP 1 ILLUMINATION FAILURE
15
LAMP 4 USAGE TIME ELAPSED
The lamp usage time exceeds the stipulated value
Lamp replaced
14
LAMP 3 USAGE TIME ELAPSED
13
LAMP 2 USAGE TIME ELAPSED
12
LAMP 1 USAGE TIME ELAPSED
11
LAMP 4 USAGE TIME WARNING
The lamp usage time exceeds the stipulated value.
10
LAMP 3 USAGE TIME WARNING
9
LAMP 2 USAGE TIME WARNING
8
LAMP 1 USAGE TIME WARNING
7
DMD LOW TEMP. ERROR
The DMD ambient temperature is lower than the stipulated value.
DMD ambient temperature at or above stipulated value
6
OUTPUT AIR TEMP. ERROR
The output air temperature exceeds the stipulated value.
Output air temperature below stipulated value
5
DMD TEMP. ERROR
The DMD ambient temperature exceeds the stipulated value.
DMD ambient temperature below stipulated value
4
INPUT AIR ERROR
The input air temperature exceeds the stipulated value.
Input air temperature below stipulated value
3
DMD LOW TEMP. WARNING
The DMD ambient temperature is lower than the stipulated value.
DMD ambient temperature at or above stipulated value
2
OUTPUT AIR TEMP. WARNING
The output air temperature exceeds the stipulated value.
Output air temperature below stipulated value
1
DMD TEMP. WARNING
The DMD ambient temperature exceeds the stipulated value.
DMD ambient temperature below stipulated value
0
INPUT AIR TEMP. WARNING
The input air temperature exceeds the stipulated value.
Input air temperature below stipulated value
Note
* Make sure to specify option FEh for this unit.
11