Panasonic RS-232C Manual Do Utilizador

Página de 49
35/49 
 
2.106. Query KEYSTONE 
Hexadecimal 02h 51h 4Bh 53h 
03h 
Character  Q K S  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 *3 *5 03h 
Character    *2 *4 *6   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
 
32 
31 
30 
Hexadecimal 2Dh 
33h 32h 2Dh 
33h 31h 2Dh 
33h 30h 
Character 
 3  2 - 3  1 - 3  0 
 30  31  32 
Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h 
Character 0 3 0 0 3 1 0 3 2 
 
2.107. Query SHIFT H 
Hexadecimal 02h 51h 48h 50h 
03h 
Character  Q H P  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 *3 *5 03h 
Character    *2 *4 *6   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
 
127 
126 
125 
Hexadecimal 2Dh  31h 32h 37h  2Dh  31h 
32h 
36h  2Dh  31h 32h 35h 
Character 
 1 2 7 - 1 2 6 - 1 2 5 
  125 126 127 
Hexadecimal 31h 
32h 35h 31h 
32h 
36h 
31h 
32h 
37h 
Character  1 2 5 1 2 6 1 2 7 
Note: 
• 
This command is not acceptable when the input is NETWORK. 
 
2.108. Query SHIFT V 
Hexadecimal 02h 51h 56h 50h 
03h 
Character  Q V P  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 *3 *5 03h 
Character    *2 *4 *6   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
 
64 
63 
62 
Hexadecimal 2Dh 
36h 34h 2Dh 
36h 33h 2Dh 
36h 32h 
Character 
 6  4 - 6  3 - 6  2 
 62 
63 
64 
Hexadecimal 36h 32h 36h 33h 36h 34h 
Character 6 2 6 3 6 4 
Note: 
• 
This command is acceptable except when the input is NETWORK. Or, this command is acceptable when the 
input is NETWORK and ASPECT is H-FIT (for FW300 series only). In other cases, ER401 is returned.