3M 800rf Manual Do Utilizador

Página de 170
23 
800rf-NA
2012 March
7-INSTALLATION AND SET-UP 
(continued)
7.9  Completion of Taping Heads
See Manual 2 for Complete Instructions:
1.  Place the Upper Taping Head in a convenient 
working position
.2. Use Figure 7-22 and tape threading label. 
Position the tape supply roll so the adhesive 
side of tape is facing the front of the taping head 
as it is pulled from the supply roll. 
3.  Attach the threading needle to the end of the 
roll. Guide the threading needle around the wrap 
roller (Position 1) then back around the one-
way tension roller (Position 2). 
4.  Continue pulling the threading needle down and 
guide it between the two (2) rollers on the apply 
arm (Position 3).
5.  Pull the threading needle down until the tape 
travels between the apply plate and the ears of 
the apply arm (Position 4) until it extends past 
the applying roller.  When properly threaded the 
adhesive side of the tape should be facing the 
knurled rollers at position 2 and also position 3. 
6.  Cut away any excess tape and repeat steps for
  
Lower Taping Head.
Important –
  Do not cut against the apply roller -  
                      roller damage could occur.
 One Way
 Tension
 Roller
 Tension
 Wrap
 Roller
 Knurled
 Roller
 Wrap
 Roller
 Applying
 Roller
 Threading
 Needle
#1
#2
#3
#4
Figure 7-27