Addtron Technology PR0017 Manual Do Utilizador

Página de 6
 
Mercury 6-5 M/E Installation guide 
Mercury Hub User Guide 
 
Top View 
 
 
 
1
9
0
1
9
0
NETWORK ID
1
2
3
UPLINK
10BASE-T
Col
Power
Vdc
1            2              3           4           5           6           7           8           9           0
Power
Vac (Option)
100 - 250 Vac
 50 - 60Hz
Rs232 Ports
Collision LED
Address selection switches
Power On LED
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Connection to Mercury Controllers: 
 
Using a standard CAT5 patch lead, connect the serial output of the RDM Controller to one of the RS232 ports 
of the Mercury Hub.  
 
RS232 Lead Lengths 
 
For mains powered hubs, patch lead maximum length must not exceed 15 metres. (ports 1 - 10) 
For Mercury powered hubs, inputs 1 and 2 patch leads must not exceed 5 metres, ports 3 - 10 must not 
exceed 15 metres. 
 
The 3-character address that will be seen on the system front end is determined by the position of the two 
Network ID rotary switches and the port the controller has been connected to. 
 
Connection to other IP equipment 
 
Use a standard CAT5 patch lead to connect other IP equipment to the Mercury Hub (such as a Futura IP 
module) into the 10Base T ports 1 or 2. 
 
Connection to another Mercury Hub or Other Ethernet Hub/switch 
 
Use a standard CAT5 patch lead from the Uplink port into a standard IP port on the next Hub. 
 
Connection to a Data Manager/Director 
 
Use a standard CAT5 patch lead and connect the Data Manager or Data Director to one of the two 10 Base T 
ports. 
 
 
Ensure that all power is 
 
 
 
switched off before   
installing or maintaining 
this product 
  
Revision 1.5 
Page 4 of 6