Tripp Lite 108 Manual Do Utilizador

Página de 45
SMART CAT5 SWITCH – 108/116
25
Input the DDC information of the monitor connected to the Smart CAT5 switch into
the memories of all connected ROC/RICCs when first installing system.
To input the DDC information:
1. Disconnect the Video cable of all ROC/RICCs from the computers.
2. Press Shift twice to open the OSD.
3. Press F10. “Please wait” flashes a few times and disappears. The monitor’s DDC
information is sent to all ROC/RICCs.
4. Reconnect the Video cable of all ROC/RICCs.
4.2.14.1 Updating the DDC information
Update the DDC information in any of the following circumstances:
 When replacing the monitor connected to Smart CAT5 Switch
 When adding a new ROC/RICC to the system
 When reconnecting an existing ROC/RICC that was temporarily used in a
different system
To update the DDC information, repeat the steps as set out above.