Cabletron Systems CSX1000 Manual Do Utilizador

Página de 644
USER’S GUIDE
318      CyberSWITCH
The average throughput is 40% for the third sample rate period. This is less than the configured 
utilization, so out of the last 3 samples (a sliding window is in use), 1 out of 3 samples have 
throughput that is greater than the configured utilization. The overload condition has still not been 
met. No extra calls are made. 
After the fourth sample rate period (20 seconds have now passed), the first sample is dropped. The 
average throughput for the new sample is below the configured utilization percentage. Therefore, 
1 out of 3 samples have throughput that is greater than the configured utilization. No extra calls are 
made.
After the fifth sample period, the second sample taken is dropped. The average throughput for the 
new sample taken is 60%. But because the sample dropped was a sample that was greater than the 
configured utilization, there still are only 1 out of 3 samples that are greater than the configured 
utilization. 
After the sixth sample period, the third sample taken is dropped. The average throughput for the 
new sample is over the configured utilization. The trigger then has been met; two out of three 
samples have met the overload condition. An extra call will be added, and the process will be reset.
C
ALL
 I
NTERVAL
 P
ARAMETERS
C
ONFIGURING
 
THE
 C
ALL
 I
NTERVAL
 P
ARAMETERS
U
SING
 CFGEDIT
1.
Select Call Intervals from the Call Control Options menu.
2.
Enter the minimum time interval between call attempts.
C
ALL
 I
NTERVAL
 C
ONFIGURATION
 E
LEMENTS
M
INIMUM
 T
IME
 I
NTERVAL
The configured call interval is the minimum time between call attempts. The system will not make 
a call attempt in less than the configured call attempt value. However, due to the system hardware 
clock resolution, the actual time interval may be greater than the configured value. The default 
value is 0.70 seconds. The range of the configured value is 0 to 5 seconds, in 1/100 second 
increments. A configured value of 0 implies that the system will make call attempts without any 
delay between them.
C
ALL
 I
NTERVAL
 B
ACKGROUND
 I
NFORMATION
This parameter allows the configuration of the minimum interval between call attempts. This 
interval applies to the entire system, including all lines, sites, and devices.
The Call Interval is configured in terms of hundredths of seconds. The default value is .7 seconds. 
The range of the configured value is 0 to 5 seconds. A configured value of 0 implies that the system 
will make call attempts without any delay between them.
The default value of .7 seconds is compliant with the Communications Industries Association of 
Japan’s(CIAJ) regulation. This regulation states that no customer premise equipment should make