Cabletron Systems CSX1000 Manual Do Utilizador

Página de 644
USER’S GUIDE
340      CyberSWITCH
files and devices depending upon its configuration. Refer to your UNIX system documentation for 
more information on syslogd.
Each log message sent to a syslogd server has a priority tag associated with it. The priority tag is 
encoded as a combination: facility.level. The facility identifies the part of the system creating the 
log message and the level describes the severity of the condition which caused the log message to 
be written.
When sending a log message to a Syslog Server, the message is formatted as an ASCII string with 
the first item in the string being the syslog priority enclosed in angle brackets. The priority is 
presented as a decimal value, not a hexadecimal value. For example, to log the string “CDR 
VERIFY” with a priority of authentication.info, the priority (26 hex) would be converted to 38 
decimal and the syslog server would be sent the string “<38> CDR VERIFY”. The Syslog daemon 
will use the priority of 38 (26 hex) to determine where the message should be sent or stored. The 
string “CDR VERIFY” will then be sent to that destination.
The priority tag is implemented as an 8 bit hexadecimal integer. The low order three bits contain 
the severity level; the high order 5 bits contain the facility. Thus, for a convenient example, level 
info is encoded as the value 6 and facility authentication is encoded as the value 4 (in BSD UNIX 
v4.3). These two fields are combined as follows:
level ‘6’ 
=> 06 hex
facility ‘4’ shifted left 3 bits to use the high order 5 bits 
=> 20 hex
bitwise OR the two values together
=> 26 hex
In result, priority of authentication.info is encoded as 26 hex.
Note:
Because the values for both the facilities and the severity levels may vary from one version 
of UNIX to the next, the system allows you to set the entire priority value as an integer. This 
integer will be prepended to all messages sent to the Syslog Server.
One of the sources from which syslogd accepts log messages is UDP port 514. This is the access 
point that the system’s CDR subsystem uses when logging to a syslog server. It sends its log 
messages to UDP port 514 at the server’s IP address. 
Syslog Servers use UDP which is a datagram service. When a datagram is sent to a Syslog Server, 
there is no acknowledgment that the datagram was properly received. To reduce the possibility of 
lost data, two Syslog Servers may be used. The two resulting log files can be compared to detect 
missing data in one or the other.
CDR L
OG
 R
EPORT
 O
VERVIEW
This option allows you select the storage destination of your CDR log reports. You may send the 
CDR log reports to the local log, or to a previously configured offnode Syslog Server(s). A total of 
three destinations may be selected. For example, you could select the local log, and two previously 
configured Syslog Servers for your CDR log reports’ destinations.
Storage on the local log is not recommended for production use; it is intended primarily for 
diagnostic use. This is because the local log only retains a fixed number of log entries. Once the file 
is full, each new entry overwrites the oldest entry. This will not give you a complete CDR Log.
CDR reports sent to the local file can be written to disk by issuing the 
log cdr write 
command. 
The file is the written to the \LOG directory. The file name is CDR_LOG. The file extensions are .1,