Verifying IP RIP
perform the verification steps. It also uses the 
show ip route
 command. The
 show ip route
 
command is used by a specific router to display the IP routing table. Substitute the equivalent 
command for your IP router.
The steps to verify the operation of IP RIP output processing on a WAN interface are:
1.
Make sure that a dedicated connection between system and Router is up and operational. On 
the system’s administration console:
Type: 
cs
<return>
If the connection to Router is displayed, the continue with the next step.
2.
Determine if Router has learned the route to 192.1.1.0 from the system. On the Router:
Type: 
show ip route
<return>
If the route to 192.1.1.0 is displayed, the IP RIP output processing is operational.
If the route is NOT displayed, refer to
 in the Problem 
Diagnosis chapter.
V
ERIFY
 IP RIP I
NPUT
 P
ROCESSING
 O
PERATIONAL
 
ON
 
A
 WAN I
NTERFACE
To verify that IP RIP Input Processing (routes learning) is properly operational on a WAN interface, 
the IP RIP processing must be successfully initialized.
The same example that is used in the previous section is used to verify IP RIP input processing on 
a WAN interface.
To verify the operation of IP RIP Input processing on a WAN interface:
1.
Make sure that a dedicated connection between system and Router is up and operational. On 
the CyberSWITCH administration console:
Type: 
cs
<return>
If the connection to Router is displayed, the continue with the next step.
2.
Determine if system has learned the route to 192.1.2.0 from the Router. On the CyberSWITCH 
administration console:
Type:
 ip route
<return>
If the route to 192.1.2.0 is displayed, the IP RIP input processing is operational.
If the route is NOT displayed, refer to 
 in the Problem 
Diagnosis chapter.
Dedicated Connection
Router
192.1.1.1
100.1.1.1
100.1.1.2
192.1.2.1
CSX1200
WORKGROUP REMOTE ACCESS SWITCH
LAN
10BASE-T
RX
TX
SERVICE
CH-2
D-CH
CH-1
SYNC
POWER
LINE
1
CH-2
D-CH
CH-1
SYNC
LINE
2
CH-2
D-CH
CH-1
SYNC
LINE
3
CH-2
D-CH
AGI
CH-1
SYNC
LINE
4