Cabletron Systems ZX-250 Manual Do Utilizador

Página de 132
4-14   SmartCell ZX-250 User Guide
PVC Connections
  Switch Administration
–•
Configure the workstations for the same subnet and VPI/VCI pair = 0/101.
The broadcasting workstation on port A1 can send traffic to the receiving workstations on ports B2, B3, and C1.
4.5.3
Connecting to Local Switch Client Through a PVC
All PVC connections to the SmartCell ZX-250 local clients use B4 (the CPU port) as the HighPort. 
Follow these instructions to connect an end node to a SmartCell ZX-250 local client through a point-to-point PVC.
s•
Use 
add pvc
 to create the PVC.
SmartCell ZX # add pvc
ConnType(PTP)                             :      
<we use a point-to-point PVC
LowPortID()                               : a1   
<for this example, we connect through port a1
LowVPI()                                  : 0
LowVCI()                                  : 100
HighPortID()                              : b4   
<HighPort must be b4
HighVPI()                                 : 0
HighVCI()                                 : 100
FwdTrafficDescriptorIndex()               : 2
BkwTrafficDescriptorIndex()               : 2
SmartCell ZX #
¢•
Use 
add ipatmclient
 to create the IP over ATM local client.
SmartCell ZX # add ipatmclient
ClientNumber(0)                           : 2      
<we use client # 2 in this example
ServerType(NONE)                          : local  
<ARP server on the switch
ServerAddress()                           :
IPAddress()                               : 10.1.1.0
NetMask(255.0.0.0)                        :
MTU(9180)                                 :
SmartCell ZX #
••
Use 
add ipatmpvc
 to associate the end node’s IP address with the PVC.
SmartCell ZX # add ipatmpvc
ClientNumber(0)                           : 2     
<specify local client number
DestinationIP()                           : 10.1.1.22  
<end node’s IP address
DestinationVPI(0)                         :
DestinationVCI(33)                        : 100   
<VCI was specified as 100
SmartCell ZX # 
T•
Connect the end node to port A1 of the SmartCell ZX-250.
Q•
Configure the end node with IP address 10.1.1.22, subnet mask 255.0.0.0, and VPI/VCI pair = 0/100.
4.5.4
Non-zero VPIs
The SmartCell ZX-250 uses 12 bits to define VPI/VCI pairs. The 
vccmask
 determines how many of the 12 bits are used 
for the VPI and how many are used for the VCI. The 
vccmask
 uses a 2-bit register to hold four different VPI/VCI 12-bit 
combinations. Table 4-1 shows the registers and the values that come preconfigured on the SmartCell ZX-250.