Cabletron Systems 2200 Manual Do Utilizador

Página de 64
Troubleshooting Checklist
Troubleshooting
4-5
4.2
TROUBLESHOOTING CHECKLIST
If the 2E253-49R is not working properly, refer to 
 for a checklist of problems, possible 
causes, and recommended actions to resolve the problem.
Table 4-2
Troubleshooting Checklist 
Problem
Possible Cause
Recommended Action
All LEDs are 
OFF.
Loss of power.
Check for proper connection of the power 
cable and its access to a live outlet.
Installed improperly.
Ensure that the 2E253-49R was installed 
properly according to the installation 
instructions in 
.
No Local 
Management 
Password screen.
Autobaud is enabled, but 
the baud rate has not yet 
been detected.
Press ENTER (RETURN) (may take up to 
four times).
Terminal setup is not 
correct.
Refer to SmartSwitch Series 2E253, 2H252, 
2H253, and 2H258 Local Management 
User’s Guide
 for proper setup procedures.
Improper console cable 
pinouts.
pinouts.
Corrupt firmware image, 
or hardware fault.
If possible, attempt to download the image to 
the 2E253-49R again. Refer to 
 
for instructions to clear NVRAM.
Cannot navigate 
beyond Password 
screen.
Improper Community 
Names Table.
1.  Refer to SmartSwitch Series 2E253, 
2H252, 2H253, and 2H258 Local 
Management User’s Guide
 for the 
Community Names Table setup.
2. If the Community Names have been 
instructions on how to set the mode switch 
to reset the Community Names to their 
default values.