Cabletron Systems 2H23-50R Manual Do Utilizador

Página de 182
Installing the Device
2H23-50R/2H33-37R User’s Guide
3-7
3.4.3
Connecting Power to the Device
To connect the device to the power sources, proceed as follows: 
1.
. To 
take advantage of the load sharing and redundancy capabilities, each 
power cord must be plugged into a dedicated ac outlet. The POWER 
LED turns on (green) and the CPU LED turns on (green) briefly.
Figure 3-5
Rear View, 2H23-50R or 2H33-37R 
2.
Observe the LANVIEW LEDs. After a successful boot, the CPU LED 
turns on (green). If the PWR LED is not green after one minute and 
turns amber, there is no power redundancy. Check the power cord 
connections and the power source. If there are no problems with the 
power cord connections or power source and the CPU LED is still not 
green, contact the Cabletron Systems Global Call Center. Refer to 
 for details.
NOTE
The 2H23-50R and 2H33-37R have two power supplies. The 
power supplies have automatic voltage sensing that allows 
connection to power sources ranging from 100–125 Vac, 2.0 A 
or 200–240 Vac, 1.0 A, 50/60 Hz. 
NOTE
It takes approximately one minute for the device to boot up.
Primary
Redundant
19601-62