Cabletron Systems 2E42-27 Manual Do Utilizador

Página de 164
Broadcast Suppression Screen
2E42-27/2E42-27R/2E43-27/2E43-27R User’s Guide
5-63
Threshold (Modifiable)
Allows the user to set the desired limit of receive broadcast frames that 
will be forwarded per port per second.
Reset Peak (Toggle)
Allows the user to reset the Peak Rate. Resetting the Peak Rate also resets 
the Time Since Peak field. The Reset Peak field toggles between YES and 
NO.
[1-12] or [13-24]
 
(Navigation Key)
When the Broadcast Suppression/Statistics screen displays, the current 
statistics are displayed for the first 12 ports. This field allows the user to 
step to a second screen for the same type of information for ports 13 
through 24. While on the second screen, the user can navigate back to the 
first screen by highlighting the [1-12] field and pressing ENTER. The user 
can change the Threshold or Reset Peak fields while in either the first or 
second screen.
5.18.1
Setting the Threshold
To set the Threshold, proceed as follows:
1.
Use the arrow keys to highlight the Threshold field for the selected 
port.
2.
Type in the numbers for the desired limit. Only enter value in 
increments of ten (for example; 10, 20, 30, etc.).
3.
Use the arrow keys to highlight the SAVE command at the bottom of 
the screen.
4.
Press ENTER. The message “SAVED OK” displays.
5.18.2
Setting the Reset Peak 
To set the Reset Peak field to YES or NO, proceed as follows:
1.
Use the arrow keys to highlight the Reset Peak field for the selected 
port.
2.
Press the SPACE bar to select YES or NO.